Size
48T, 96T, 96T×5, 96T×10, 96T×100
Stabillity at RT
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the
Applications
Enzyme-linked immunosorbent assay for Antigen Detection.
Detection Range
0.156-10ng/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.054ng/mL
Specificity
No significant cross-reactivity or interference between Forkhead Box Protein O3 (FOXO3) and analogues was observed.
This assay has high sensitivity and excellent specificity for detection of Forkhead Box Protein O3 (FOXO3).
Research Area
Autoimmunity
Developmental science
Immune molecule
Signal transduction
Tumor immunity
Organism species
Mus musculus (Mouse)
Alternative Names
FOX-O3
Item Name
Forkhead Box Protein O3
Assay Length
3h
Method
Double-antibody Sandwich
Sample Type
Tissue homogenates and other biological fluids.
Assay Procedure
1. Prepare all reagents, samples and standards
2. Add 100µ
3. Aspirate and add 100µ
4. Aspirate and wash 3 times
5. Add 100µ
6. Aspirate and wash 5 times
7. Add 90µ
8. Add 50µ
C
C
C
C
L Stop Solution. Read at 450nm immediately.
L Substrate Solution. Incubate 10-20 minutes at 37°
L prepared Detection Reagent A. Incubate 1 hour at 37°
L prepared Detection Reagent B. Incubate 30 minutes at 37°
L standard or sample to each well. Incubate 2 hours at 37°
Test Principle
10nm. The concentration of Forkhead Box Protein O3 (FOXO3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Forkhead Box Protein O3 (FOXO3). Standards or samples are then added to the appropriate micro
Precision
CV(%) = SD/meanX100
Inter-Assay: CV<12%
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Forkhead Box Protein O3 (FOXO3) were tested on 3 different plates, 8 replicates in each plate.
Intra-Assay: CV<10%
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Forkhead Box Protein O3 (FOXO3) were tested 20 times on one plate, respectively.
Assay procedure summary
1. Prepare all reagents, samples and standards
UniProt ID
Q9WVH4