ELISA Kit for EGF Like Domain Protein, Multiple 6 (EGFL6)
  • ELISA Kit for EGF Like Domain Protein, Multiple 6 (EGFL6)

ELISA Kit for EGF Like Domain Protein, Multiple 6 (EGFL6)

Ref: CC-SEQ268Hu
96T

Información del producto

ELISA Kit for EGF Like Domain Protein, Multiple 6 (EGFL6)

Click here for manual in PDF

Click here for OD image

Información adicional
Size 48T, 96T, 96T×5, 96T×10, 96T×100
Stabillity at RT



The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the

Applications Enzyme-linked immunosorbent assay for Antigen Detection.
Detection Range 93.75-6,000pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 35.95pg/mL
Specificity



No significant cross-reactivity or interference between EGF Like Domain Protein, Multiple 6 (EGFL6) and analogues was observed.
This assay has high sensitivity and excellent specificity for detection of EGF Like Domain Protein, Multiple 6 (EGFL6).

Research Area Signal transduction
Organism species Homo sapiens (Human)
Alternative Names MAEG
Item Name EGF Like Domain Protein, Multiple 6
Assay Length 3h
Method Double-antibody Sandwich
Sample Type Serum, plasma, tissue homogenates and other biological fluids
Assay Procedure 1. Prepare all reagents, samples and standards
2. Add 100µ
3. Aspirate and add 100µ
4. Aspirate and wash 3 times
5. Add 100µ
6. Aspirate and wash 5 times
7. Add 90µ
8. Add 50µ














C
C
C
C
L Stop Solution. Read at 450nm immediately.

L Substrate Solution. Incubate 10-20 minutes at 37°
L prepared Detection Reagent A. Incubate 1 hour at 37°
L prepared Detection Reagent B. Incubate 30 minutes at 37°
L standard or sample to each well. Incubate 2 hours at 37°
Test Principle 10nm. The concentration of EGF Like Domain Protein, Multiple 6 (EGFL6) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to EGF Like Domain Protein, Multiple 6 (EGFL6). Standards or samples are then added to the appro
Precision



CV(%) = SD/meanX100

Inter-Assay: CV<12%

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level EGF Like Domain Protein, Multiple 6 (EGFL6) were tested on 3 different plates, 8 replicates in each plate.

Intra-Assay: CV<10%

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level EGF Like Domain Protein, Multiple 6 (EGFL6) were tested 20 times on one plate, respectively.

Assay procedure summary 1. Prepare all reagents, samples and standards
UniProt ID Q8IUX8

Enviar un mensaje


ELISA Kit for EGF Like Domain Protein, Multiple 6 (EGFL6)

ELISA Kit for EGF Like Domain Protein, Multiple 6 (EGFL6)