Stabillity at RT
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the
Applications
FLIA Kit for Antigen Detection.
Detection Range
0.98-1000pg/mL
Sensitivity
The minimum detectable dose of this kit is typically less than 0.327 pg/mL
Specificity
No significant cross-reactivity or interference between 2',5'-Oligoadenylate Synthetase Like Protein (OASL) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
This assay has high sensitivity and excellent specificity for detection of 2',5'-Oligoadenylate Synthetase Like Protein (OASL) ,etc. by FLIA (Flow Luminescence Immunoassay).
Research Area
FLIA Kit for Antigen Detection.
Organism species
Homo sapiens (Human)
Alternative Names
59 kDa 2'-5'-oligoadenylate synthase-like protein
TRIP14
Thyroid receptor-interacting protein 14
p59OASL
Item Name
2',5'-Oligoadenylate Synthetase Like Protein
Assay Length
3h
Method
Double-antibody Sandwich
Sample Type
Serum, plasma, cell lysates and other biological fluids
Format
48T, 96T, 96T×5, 96T×10, 96T×100
Assay Procedure
Double-antibody Sandwich
Test Principle
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinyla
proportional to the concentration of analytes of interest in the sample.
Precision
CV(%) = SD/meanX100
Inter-Assay: CV<12%
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 2',5'-Oligoadenylate Synthetase Like Protein (OASL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
Intra-Assay: CV<10%
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 2',5'-Oligoadenylate Synthetase Like Protein (OASL) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Assay procedure summary
 
 
 
 
1. Preparation of standards, reagents and samples before the experiment
2. Add 100μL standard or sample to each well,
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°
4. Wash plate on magnetic frame for three times
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°
6. Wash plate on magnetic frame for three times
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
C on shaker
C on shaker
C on shaker
add 10μL magnetic beads, and incubate 90min at 37°
UniProt ID
Q15646