Multiplex Assay Kit for 2-Arachidonoylglycerol (2-AG) ,etc. by FLIA (Flow Luminescence Immunoassay)
  • Multiplex Assay Kit for 2-Arachidonoylglycerol (2-AG) ,etc. by FLIA (Flow Luminescence Immunoassay)

Multiplex Assay Kit for 2-Arachidonoylglycerol (2-AG) ,etc. by FLIA (Flow Luminescence Immunoassay)

Ref: CC-LMO443Ge
96T

Información del producto

Multiplex Assay Kit for 2-Arachidonoylglycerol (2-AG) ,etc. by FLIA (Flow Luminescence Immunoassay)

Click here for manual in PDF

Click here for image

Información adicional
Stabillity at RT



The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.

To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the

Applications FLIA Kit for Antigen Detection.
Detection Range 0.29-300ng/mL
Sensitivity The minimum detectable dose of this kit is typically less than 0.097 ng/mL
Specificity



No significant cross-reactivity or interference between 2-Arachidonoylglycerol (2-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
This assay has high sensitivity and excellent specificity for detection of 2-Arachidonoylglycerol (2-AG) ,etc. by FLIA (Flow Luminescence Immunoassay).

Research Area FLIA Kit for Antigen Detection.
Organism species Pan-species (General)
Item Name 2-Arachidonoylglycerol
Assay Length 3h
Method Competitive Inhibition
Sample Type Serum, plasma and other biological fluids
Format 48T, 96T, 96T×5, 96T×10, 96T×100
Assay Procedure Competitive Inhibition
Test Principle Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is lau
proportional to the concentration of analytes of interest in the sample.
Precision



CV(%) = SD/meanX100

Inter-Assay: CV<12%

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level 2-Arachidonoylglycerol (2-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.

Intra-Assay: CV<10%

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level 2-Arachidonoylglycerol (2-AG) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.

Assay procedure summary  
 
 
 
1. Preparation of standards, reagents and samples before the experiment
2. Add 50μL standard or sample to each well,

3. Wash plate on magnetic frame for three times
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°
5. Wash plate on magnetic frame for three times
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.











C on shaker
C on shaker
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 90min at 37°
UniProt ID -